Patient monitor
1.ECG
1) Heart rate monitoring range: 0-300bpm
2) Accuracy of fetal heart rate calculation: 1bpm
3) Accuracy of fetal heart rate: 1%
4) ECG amplification bandwidth: 0.05Hz-100Hz
5) Lead selection: GND, standard; limb purpose pressure lead avR, avL & avF; chest lead: V1-V6
6) ST monitoring: -2.0-2.0mv
7) The out of gear analyze of heart rate: have
8) Pole cast indication: acousto, light display
9) Scan speed: 12.5, 25, 50mm/sec
10) Plus selection: x1/2, x1, x2, auto
11) Protection: insulated ensure 4000vAc/50HZ voltage
12) Lead wire: adult ECG power cable and lead wire
13) Alarm: the upper & lower limit of alarm value can be set, memorize automatically
2.Non-invasive blood pressure
1) Measuring technology: Automatic measurement by smart oscillating method
2) Measuring parameter: systolic pressure, diastolic pressure, mean pressure, pulse
3) Operating pattern: hand mode, automatic mode, 5mins measuring continuous
4) Measuring range: adult: 10-300mmHg Infant: 10-200mmHg New-born: 10-135mmHg
5) Cuff pressure range: 0-320mmHg
6) Unit: mmHg/kPa
7) Cuff: standard accessories: adult cuff
Optional accessories: infant cuff, new-born cuff
8) Cuff inflation time: <10secs
9) Measuring air release time: <20secs
10) Alarm: the upper & lower limit of alarm value can be set, memorize automatically
3.Pulse oxygen saturation
1) Method: chest impedance mode
2) Measuring range: 0-120bpm
3) Accuracy: 2bpm
4) Alarm: the upper & lower limit of alarm value can be set, memorize automatically
4.Body temperature
1) Measuring range: 15-45℃
2) Accuracy of calculation rate: 0.1 ℃
3) Accuracy: 0.1℃
4) Probe: standard accessories: perpetual body temperature probe
Optional accessories: esophagus body temperature probe, rectum body temperature probe
5) Alarm: the upper & lower limit of alarm value can be set, memorize automatically
5.Blood oxygen
1) Indication: blood oxygen numerical value, pulse histogram, wave pattern, pulse
2) Blood oxygen range: 0-100% adult/infant/new-born
3) Accuracy of calculation rate: 1%
4) Accuracy: 1% (70%-100%) 2% (50%-69%)
5) Pulse range: 0-255bpm
6) Pulse accuracy: 2bpm
7) Sensor: standard accessories: adult finger mode
Optional accessories: infant nip mode, new-born binding Mode
1) Heart rate monitoring range: 0-300bpm
2) Accuracy of fetal heart rate calculation: 1bpm
3) Accuracy of fetal heart rate: 1%
4) ECG amplification bandwidth: 0.05Hz-100Hz
5) Lead selection: GND, standard; limb purpose pressure lead avR, avL & avF; chest lead: V1-V6
6) ST monitoring: -2.0-2.0mv
7) The out of gear analyze of heart rate: have
8) Pole cast indication: acousto, light display
9) Scan speed: 12.5, 25, 50mm/sec
10) Plus selection: x1/2, x1, x2, auto
11) Protection: insulated ensure 4000vAc/50HZ voltage
12) Lead wire: adult ECG power cable and lead wire
13) Alarm: the upper & lower limit of alarm value can be set, memorize automatically
2.Non-invasive blood pressure
1) Measuring technology: Automatic measurement by smart oscillating method
2) Measuring parameter: systolic pressure, diastolic pressure, mean pressure, pulse
3) Operating pattern: hand mode, automatic mode, 5mins measuring continuous
4) Measuring range: adult: 10-300mmHg Infant: 10-200mmHg New-born: 10-135mmHg
5) Cuff pressure range: 0-320mmHg
6) Unit: mmHg/kPa
7) Cuff: standard accessories: adult cuff
Optional accessories: infant cuff, new-born cuff
8) Cuff inflation time: <10secs
9) Measuring air release time: <20secs
10) Alarm: the upper & lower limit of alarm value can be set, memorize automatically
3.Pulse oxygen saturation
1) Method: chest impedance mode
2) Measuring range: 0-120bpm
3) Accuracy: 2bpm
4) Alarm: the upper & lower limit of alarm value can be set, memorize automatically
4.Body temperature
1) Measuring range: 15-45℃
2) Accuracy of calculation rate: 0.1 ℃
3) Accuracy: 0.1℃
4) Probe: standard accessories: perpetual body temperature probe
Optional accessories: esophagus body temperature probe, rectum body temperature probe
5) Alarm: the upper & lower limit of alarm value can be set, memorize automatically
5.Blood oxygen
1) Indication: blood oxygen numerical value, pulse histogram, wave pattern, pulse
2) Blood oxygen range: 0-100% adult/infant/new-born
3) Accuracy of calculation rate: 1%
4) Accuracy: 1% (70%-100%) 2% (50%-69%)
5) Pulse range: 0-255bpm
6) Pulse accuracy: 2bpm
7) Sensor: standard accessories: adult finger mode
Optional accessories: infant nip mode, new-born binding Mode