Anesthesia Machine

MHJ-IIIB Anaesthesia Machine
Main Specifications:
1.flowmeter measuring range:
O2 flow 0.1~10L/min
N2O flow 0.1~10L/min
2.Gas supply: 0.27~0.55mPa
3.O2 flush: 35~70L/min
4.N2O cut off:O2 preesure drops below 0.1 Mpa
5. Enflurane vaporizer:0-5% adjustable
6.APL: 0.5~7Kpa
7.Dimension: 516x6000x1370mm (LxWxH)
8.Weight: 52Kg
The anesthesia machine of popular type MHJ-3B with SC-M5 anesthesia ventilator forms a complete anesthesia system
Feathers:
1.New design of flowmeter with ORC(oxygen Ratio Control) to guarantee at leas 30% O2 concentration
2.Automatic N2O cut off
3.ISO standard circle system fittable to the left or the right side of the machine makes operation more convenient in either side
4.Easy opservation of respiratory pressure from pressure gauger
5.With Enflurane or Isoflurane vaporizer
6.Attachabe cylinder support
MHJ-IIIB Anaesthesia Machine,a new popular type machine, has not only made a big step in increasing its reliability,safety and combination but also,in design,given room to equip anaesthesia ventilator and monitoring to form a complete versatile anaesthesia maching thus provides more useful functions.
ISO standard circle system can meet the needs for semiopen semi-closed or closed system anaesthesia.The machine has a DZFG vaporizer with adjustable anaesthetic concentration. The machine is easy in operation.
MHJ-IIIB1 Anaesthesia Machine
Main Specifications:
1.Supply pressure:0.27~0.55MPa
2.Flow control: O2 0.1~10L/min
N2O 0.1~10L/min
3.ORC system: Oxygen not less than 25% within mixture gas
4.N2O automatic cut-off:Active when oxygen pressure less than 0.1MPa
5.O2 flush:50±10L/min at O2 pressure of 0.45MPa
6.Adjustment concentartion of Enflurane Vaporizer:0~5Vol%
7.Airway pressure limit range(APL): 0.5~7kpa
8. SC-M3A1 anaesthesia ventilator working type:Pneumatic-controlled and pneumatic-criven,time cycle,volume constant
9. Ventilation frequency:6~40L/min
10. Minute volume:3~18L/min
11. I:E ration:1:1.5 (fixed)
12. Gas consumption:less than 0.8L/min(for control part)
13. Dimensions:516×600×1370(L×W×H)
14. Weight:60kg
15. No need of power supply. Only compressed oxygen for pneumatic driving and pneumatic control.
MHJ-III B1 is a standard anaesthesia machine with multifunctions which is composed of basic anaesthesia machine,anaesthesia ventilator and pressure monitorings. MHJ-III B1 is designed with techniques for reliability and safety and adopted a modular system for easier combination with various anaesthesia ventilators and monitorings to enhance is functions.
The standard MHJ-IIIB1 includes a pneumatic-controlled and pneumatic-driven anaethesia machine SC-M3A1,an anaesthesia circuit model IV and an economic anaestheisa vaporizer DZFG.MHJ-III B1 is suitable for use in various hospital for closed-anaesthesia,semi-closed anaesthesia and semi-open anesthesia,and for oxygen inhalation during resuscitation.
* A flowmeter with ORC system ensures oxygen concentration not less than 25%.
* With automatic N2O cut-off
* O2deficiency alarm
* SC-M3A1 anesthesia ventilator,with easy operation and low air consumption
* Top plate intended for all kinds of monitors
MHJ-III-B2 anaesthesia machine
MHJ-III-B2 multifunction anaesthesia machine,developed with reliabilit,safety,practicability,combination in mind,is a kind of up to date economic anaesthesia machine with modular system.Standard parts of MHJ-IIIB2 include anaesthesia ventilator SC-M3A,a compact vaporizer and airway gauge.It is possible to be furnished with other types of vaporizers and electronic monitorings to make an ideal multifunction anaesthesia machines for modern hospital.
Feathers:
1.ISOcircuit system adaptable to various monitoring
2.New type of flowmeter ORC system (O2concentration no less than 25%),N2O cut off safety unit.
3.Conpact Enflurane Vaporizer:Vaporized drug comcentration adjustable
4.The SC-M3A pneumatic anaesthesia ventilator was comparable small consumption of gas(one cylinder of Oxygen for six hours of operation),and precise parameters for control Airway pressure gauge for real-time display of respiration of patient.
Technical Data:
1.Flow control range:O2 (0.1~10L/min)
N2O(0.1~10L/min)
2.Gas Supply:0.27~0.55MPa
3.O2Flush:35~70L/min
4.N2O automatic cut-off:active when O2 pressure lower than 0.1MPa
5.Non-compensation Vaporizer(Enflurane)
Cncentration adjustable(0~5%)
6.Anaesthesia Ventilator:
Control type:Pneumatically driven and controlled,time cycle and volume constant
Gas supply:0.27~0.55Mpa
Frequency:6~40cycles/min
I:E ratio:1:2(Fixes)
Tidal volume: Adule bellow 150~1600ml
Children bellow 50~150ml
Safety Valve Working Pressue:6kPa
Anesthesia Machine MHJ-IIIB3
With Two Vaporizers and Intergrated Circuit.
Feathers:
Adopts a two stage regulator and a hight precision three-gas flowmeter with ORC system,ensures oxygen concentration not less than 25%
Automatic N2O cut off and an unique O2 deficiency alarm divice.
With Enflurane or lsoflurane vaporizer,or both.
Attachable cylinder bracket.
Pneumatic-driven and electic-controlled anesthesia ventilator(Optional)
With constant volume for adults and children(With Ventilator).
Real time airway measurement
Exhaled tidal volume and Minute vlulme measurement(Optional).
Stainless steel ansesthesia writing surface

Volummeter(Optional) and Pressure gauge
Respiratoy monitor andAnaesthesia ventilator (Optional)
Technical Data:
Gas supply: O2:2.7-5.5mPa;
N2O:2.7-5.5mPa;
Air:2.7-5.5mPa;
Flow control range:O2:0.1-10L/min;
N2O:0.1-10L/min;
Air:0.1-10L/min;
Oxygen deficiency alarm:as oxygen pressure is=0.2Mpa,alarm occurs and lasts 7 seconds ast least;
N2O cut-off:N2O is cut-off completely,when O2 pressure is=0.1Mpa;
O2 flush:50±10L/min at O2 pressure 0.45Mpa;
Enflurane vaporizer:0.2-5VOL%,adjustable;
APL:0.5-7Kpa
SC-M3A1 anaesthesia ventilator working mode:
Pneumatic-controlled and pneumatic-driven,time cycled,volume constant(Optional)
Dimension:1275×584×655mm
Weight:80Kg
Standard Accessories
·Main Unit
·Enflurane DZFG Vaporizer
·Version IV Circuit System
·Air Supply Hose
·Common Gas Hose
·Patient Pipeline
·Breathing Bag
·Real Time Pressure Gauge
Optional Accessories
·Isoflurane DZFG Vaporizer
·Cylinder Assembly
·Anaesthesia Ventilator
·Volummeter
·APL Valve
·O2 Reducer
·N2O Rdducer
·Air Hose
·Integrated Circuit